Auxiliary Heater for Panasonic Air Handler
Auxiliary Heater for Panasonic Interios Central Heat Pump Systems.
- Choose the correct Auxiliary Heater size to support your heating requirements
- Compatible with both R454B and R410A Panasonic INTERIOS™ Air handlers
- Refer to the Installation guide for Air Handler / Auxiliary Heater size compatibility
- Submittal Sheet - HVAC - Auxiliary Heating Kit (3 kW) - CZ-FM03P
- Submittal Sheet - HVAC - Auxiliary Heating Kit (5 kW) - CZ-FM05P
- Submittal Sheet - HVAC - Auxiliary Heating Kit (8 kW) - CZ-FM08P
- Submittal Sheet - HVAC - Auxiliary Heating Kit (10 kW) - CZ-FM10P
- Submittal Sheet - HVAC - Auxiliary Heating Kit (15 kW) - CZ-FM15P
- Submittal Sheet - HVAC - Auxiliary Heating Kit (20 KW) - CZ-FM20P
- Submittal Sheet - HVAC - Auxiliary Heating Kit (25 kW) - CZ-FM25P
- Installation Manual - HVAC - Auxiliary Heater
- Heat Pump Solutions Catalog - HVAC - INTERIOS™ Central Heat Pump Systems
Specifications
| SKU | CZ-FM03P | CZ-FM05P | CZ-FM08P | CZ-FM10P | CZ-FM15P | CZ-FM20P | CZ-FM25P |
|---|---|---|---|---|---|---|---|
| Operating Voltage (V, Ph, Hz) | 208 / 230, 1, 60 | 208 / 230, 1, 60 | 208 / 230, 1, 60 | 208 / 230, 1, 60 | 208 / 230, 1, 60 | 208 / 230, 1, 60 | 208 / 230, 1, 60 |
| Current (A) | 10.8 / 12 | 18 / 20 | 28.8 / 32 | 36.1 / 40 | 54.1 / 60 | 72.1 / 80 | 90.1 / 100 |
| Heat Power (kW) | 2.25 / 2.75 | 3.75 / 4.6 | 6 / 7.35 | 7.5 / 9.2 | 11.25 / 13.8 | 15 / 18.4 | 18.75 / 23 |
| MCA (A) | 14 / 16 | 23 / 27 | 37 / 42 | 46 / 53 | Circuit 1: 23 / 27 Circuit 2: 46 / 53 |
Circuit 1: 46 / 53 Circuit 2: 46 / 53 |
Circuit 1: 23 / 27 Circuit 2: 46 / 53 Circuit 3: 46 / 53 |
| Max Fuse (A) | 15 / 20 | 25 / 30 | 40 / 45 | 50 / 60 | Circuit 1: 25 / 30 Circuit 2: 50 / 60 |
Circuit 1: 50 / 60 Circuit 2: 50 / 60 |
Circuit 1: 25 / 30 Circuit 2: 50 / 60 Circuit 3: 50 / 60 |